ARMATURE LIFT
PROCEDURE:
STEP 1
Assemble the gauge head DX75630 (n°11 case 1) with the dial gauge and fit it in the dedicated front slot. Set the instrument in microns.
STEP 2
Close completely the injector being sure to tight the solenoid with the correct torque specified in the Tricky-Tech data sheet for the injector that has to be tested.
Fix the body injector in the dedicated centering plate as shown in the picture. Choose a part of the body to avoid the uncorrect centering (avoid bavels).
STEP3
Be sure that the electrical connection of the Turan are well connected (Control unit, EPS, laptop).
STEP4
Open the Turan software and click on the "Start" button.
Select "Denso" on the "Type" menu and the code of the injector to test on the "Inj code" menu.
STEP5
Click on "Coil lift" on the test menu selection and, using the dedicated terminal cable, connect the "coil" cable to the injector.
Move down the movable crossbeam so that the gauge head can pass into the solenoid hole. Stop when the gauge head touches the armature inside the solenoid. Be sure that the head does not get stuck on the solenoid spring.
STEP6
Lock the vertical and longitudinal motion.
STEP7
On the Turan software select “Auto” on the “Coil lift reading” menu and wait until the gauge start to communicate with the software.
Activate the reading by clicking on the “Activate Inj Ind” button and wait until the software ends the test.
On the “Lift measured μm” window will appear the value of the coil lift electrically measured.
By clicking the “Report” button placed in the top right side of the Turan window, is possible to know the limit values of the examined injector.
END